Downloaded from https://www.everyspec.com FM 1-509 flowing around poppet C, and exiting through the return port. If the cam is rotated 45° from the position shown in Figure 8-12, all the poppets are seated, and the selector valve is in a neutral position. The spool-type, radial selector valve operates in the same manner as the poppet type. The spools are plungers within the valve housing. Drilled or cutaway passages in the spools are aligned with drilled passages in the valve housing when the spools are raised by the cam. Compound Selector Valve. To conserve space and to make installation easy when banks of units must be controlled, several selector valves are compounded into one unit.
Each selector valve is controlled independently, but only one connection is needed for the pressure line and one for the return line. CONTROL VALVES Purpose. Hydraulic valves control movement or pressure of fluids in hydraulic systems. Generally, all valves are control valves; however, for some Army aircraft, the term “control valve” identifies a valve that controls the direction of flow through alternate channels. Such a valve does not do quite as much in the control of fluid flow as the selector valve does; the control valve functions more like a shutoff valve. Operation.
Although some control valves have more than three ports, the valve most commonly referred to in Army aircraft as a control valve is 8-9