everyspec.com hydraulic manual — Chapter 8 - Flow Control Units

Downloaded from https://www.everyspec.com FM 1-509 Fluid under pressure will flow through the now unblocked selector valve cylinder port and will enter the left chamber of the servo cylinder housing. The piston will be forced to the right and will carry the selector valve housing with it since that housing is welded to the piston rod. When the piston has moved to the right exactly 0.250 inch, the selector valve housing will have moved to the right over the now stationary pilot valve. This action will return the selector valve to the OFF position. Since the flow of fluid is now stopped, the piston will travel no farther.

If it is necessary to move the servo piston to the limit of its possible travel within the cylinder bore, continue moving the pilot valve ahead so that the selector valve housing is unable to catch up with the pilot valve. In most cases, the pilot valve is operated by remote control. The servo sloppy link is the point of interconnection between the control linkage, the servo pilot valve, and the servo piston rod. It provides a limited amount of slack between them. This enables the pilot valve to be moved to the ON position without the linkage directly moving the piston rod. The slack provided by the sloppy link is necessary for the normal powered movement of the servo to take place.

The limitation in the amount of movement that can take place in the sloppy link provides two benefits: a stop is provided for the pilot valve movement, and the manual movement of the servo piston can be made without any strain on the pilot valve. All servos used in aircraft systems incorporate some form of sloppy link. In some servos, a bypass valve is provided to reduce the servo’s resistance to movement whenever it has to be moved manually. The bypass valve automatically opens a free-flow pathway between the chambers on each side of the piston when no operating pressure is available to the servo. It automatically closes the free-flow pathway whenever the servo has operating pressure.

Fluid can be forced in and out of the servo chambers during manual operation without much manual effort. In some hydraulic servos, the selector valve is actuated by an electrical input control signal rather than by a manual input control signal. Such signals can be provided by some aircraft flight-position- sensitive sensing device (for example, a gyro or an aneroid altimeter) that permits the servo to provide semiautomatic control of an aircraft’s flight. Two types of electroservos are used in some late model cargo helicopters: extensible links and stability augmentation servos.

However, these electroservos will not be discussed here because their complex design and operation are beyond the scope of this manual. IRREVERSIBLE VALVES Purpose. Irreversible valves assist hydraulic servos the same as ratchet valves assist actuating cylinders; both ratchet and irreversible valves guard against the movement of the unit by an externally applied 8-26