Downloaded from https://www.everyspec.com FM 1-509 CAUTION NEVER EXCEED 50 PSI WHEN CHARGING THE FLUID DISPENSER. CAUTION MAKE SURE A SUFFICIENT AMOUNT OF FLUID IS MAINTAINED IN THE FLUID DISPENSER DURING BLEEDING OPERATIONS. After bleeding, always check the system reservoir to ensure that it is full of hydraulic fluid. Gravity Method. In the gravity method, the air is expelled from the system through one of the bleeder valves on the brake assembly. To bleed the system using this method, attach a bleeder hose to the bleeder valve. (See Figure 10-18.) Then place the free end of the hose in a container holding enough hydraulic fluid to cover the end of it.

The air-laden fluid is then forced from the system by applying the brakes. If the brake system is part of the main hydraulic system, use a portable hydraulic test stand to supply the pressure. If the system is an independent master cylinder system, use the master cylinder to supply the necessary pressure. In either case, close the bleeder valve each time the brake pedal is released; otherwise air will be drawn back into the system. Bleeding should continue until no more air bubbles come through the bleeder hose into the container. 10-17