Downloaded from https://www.everyspec.com FM 1-509 After the replacement tube has been permaswage repair procedure in steps 18 made, swage the tube using the through 32 below. 18. Mark tube ends. Use the correct marking tool for the size of the tube to be swaged. When marking with tool 09862, place the lip stop against the end of the tube. (See Figure 2-7.) Using the slot as a guide, mark the tube in two places (180° apart) with the marking pen. If marking tool 09862 and marking pen D10058 are not available, see the chart in Figure 2-7 for the tube insertion band. 19. Position the prepared tube within the fitting. Align the mating ends and position the union fitting.
Check to see if the separable fitting can be swaged with the fitting installed on the component. If not, mark the fitting and tube so that proper clocking is obtained. Then swage the fitting off the aircraft using steps 20 through 32 below. 20. Connect the hydraulic pressure line from the portable hydraulic power supply to the fitting on the base of the swaging tool. 21. Set the selector valve on the power supply to EXHAUST to relieve all line pressure. 22. Install the set of die blocks in the swaging tool. Position the tool below the level of the power supply. These steps will 2-10