Downloaded from https://www.everyspec.com FM 1-509 CHAPTER 4 SYSTEM RESERVOIRS PURPOSE The system reservoir holds enough fluid to keep the hydraulic system operating properly. It also replaces fluid lost through minor leakage or evaporation. Reservoirs-- Provide space for fluid volume that increases over the initial amount; for example, an increase might occur through thermal expansion or foaming. Provide an escape for air trapped in the system. Help cool the system fluid. TYPES The two types of reservoirs used in aircraft hydraulic systems are the in-line type and the integral type.
The in-line reservoir has its own housing, is complete within itself, and is connected with other components in the system by tubing or hose. The integral type consists of a space that is set aside within some major component to hold a supply of operational fluid; it has no housing of its own. The in-line reservoir is the type commonly used in Army aircraft. A space is provided in the in-line reservoir above the normal fluid level for fluid expansion. This space also enables trapped air to escape. Reservoirs are never intentionally filled to the top with fluid. In fact, most reservoirs are designed so that they cannot be overfilled during servicing.
This is done by locating the rim of the filler neck below the top of the reservoir. Most reservoirs have a dipstick or glass-sight gage that enables the fluid level to be easily and accurately checked. All reservoirs are either vented (open to the atmosphere) or pressurized (closed to the atmosphere). Vented Reservoirs. In vented reservoirs, atmospheric pressure and gravity are the forces which cause fluid to flow out of the reservoir and into the pump. To supply a pump with fluid, a vented reservoir must be positioned at a higher location than the pump. If the reservoir and the pump were at the same level, gravity would have no effect on fluid flow.
If the reservoir was at a level below the pump, fluid would tend to run out of the pump and into the reservoir. Most hydraulic system reservoirs of current Army aircraft are vented. 4-1