Downloaded from https://www.everyspec.com FM 1-509 Finger Strainers. Many reservoirs have strainers in the filler neck to keep foreign matter from entering the reservoir when the filler cap is off. These strainers are made of fine gauze and are called finger strainers because of their shape. Finger strainers should never be removed or punctured to speed the pouring of fluid into the reservoir. Filter Elements. Filter elements filter the air before it enters the reservoir or the fluid before it leaves the reservoir. An air-vent filter element is located in the upper part of the reservoir above the fluid level. A fluid filter element is located at or near the bottom of the reservoir.
Fluid returning to the reservoir surrounds the filter element and flows through the wall of the element. This leaves any fluid contaminant on the outside of the element. The fluid filter elements commonly used in aircraft reservoirs are made of treated cellulose formed into accordion-like pleats. This construction exposes the fluid to the maximum amount of filter surface within a given space. Reservoirs having filter elements have a bypass valve to ensure that the pump will not be without fluid even if the filter element becomes clogged. This valve is normally held closed by a spring; it would be opened by the stronger partial vacuum if the element became badly clogged.
Figure 4-4 shows a reservoir with all the filter elements. 4-4