everyspec.com hydraulic manual — Chapter 5 - System Filters

Downloaded from https://www.everyspec.com FM 1-509 Two-Stage Fluid Filters. Two-stage line-type hydraulic system filters are being used in some recent aircraft models. The typical two-stage filter has two filter elements, two bypass valves, and two differential pressure indicators. The first-stage element can filter out smaller particles than the second-stage element can. Normally the fluid passes through both elements, flowing first through the first-stage element and then through the second-stage element. No foreign matter will be left for the second-stage element to remove as long as the first-stage element is unclogged and functioning.

If the first-stage element becomes clogged, its bypass valve opens and fluid goes directly from the filter inlet port to the second-stage element, which takes over the job of filtering out foreign particles. Although the second-stage element is not capable of filtering out the very small particles, it can be used until the first-stage element is unclogged. AIR FILTERS An air filter is usually located in the line leading into the system supply source. Additional filters may be located at various points in the system lines to remove any foreign matter that may enter the system. Like hydraulic filters, air filters have a removable element and a built-in relief valve.

The relief valve opens and bypasses the air supply around the filter element in case the element becomes clogged. Some air filters are equipped with a paper-type element which must be replaced periodically. Others have a mesh-type screen which requires periodic cleaning. The mesh-type screen may be returned to the system after being cleaned and dried. MAINTENANCE Filters should be serviced according to the schedules and procedures in technical manuals on the specific aircraft involved. However, the following guidelines apply to the maintenance of all aircraft hydraulic system filters: Handle filters carefully.

A hole no larger than a pinprick will permit large foreign particles to pass through the element. Service filters in a clean area. This will prevent dirt and other foreign particles from entering the system while the filter is being serviced. Do not leave a disassembled filter housing unprotected; this may cause contamination. Remove wrappings from a replacement element only when the element is to be inspected or installed. Hand-tighten the filter bowl to the head. Always safety the bowl and head together. 5-7