FM 1-509 Downloaded from https://www.everyspec.com need for pump output is actuator travel because reduced to zero. The pump senses the end of the the unused output causes a sudden increase in . . discharge pressure. As this pressure reaches the setting of the compensator valve, it pushes the valve to the right. The pressure then pushes on to the control piston, causing it to move to the left and decreasing the angle of the cam plate. This action decreases the effective length of the piston stroke and the volume of fluid delivered to the system. In actual operation, the cam plate assumes various angles to maintain the proper system pressure.
It will meet all fluid demand conditions within the rating of the pump. A pump check valve (A) installed in the pump outlet line prevents a return flow into the pump during the system’s operation using a portable hydraulic test stand. The reverse flow of hydraulic fluid motorizes the pump. Maintenance. Hydraulic power pumps are repaired and overhauled at depots. This work requires special tools and equipment. 6-10