FM 1-509 Downloaded from https://www.everyspec.com Malfunctions. Since hand pumps are only operated for short periods of time, malfunctions do not occur often. However, the most common cause of malfunctioning is failure of the check valves. Failure of either check valve will cause the hand pump to become completely inoperative. Some designs have a third check valve in the pressure (out) line which reduces this problem. With this design, even if one of the check valves or the piston-head seal should fail, the pump could still produce pressure on at least one stroke of the cycle. The third check valve prevents system pressure from reaching the hand pump during the system’s normal operation.
It also aids the mechanic in determining hand pump failure. If the check valve in the inlet port leaks, the pump will develop pressure on the piston extension stroke only. If the check valve in the piston rod leaks or if the piston-head seal leaks, the pump will develop pressure on the piston retraction stroke only. If the pressure (out) line check valve leaks, no immediate indication that this is happening will occur. In this case, the pump will still develop pressure on both strokes. Maintenance. Basically, the care of hand pumps consists of disassembly, inspection, reassembly, and testing.
After disassembly, thoroughly clean all parts and carefully inspect them for nicks, cracks, scratches, and corrosion. Inspect threaded surfaces for damaged threads and piston shaft and springs for distortion. Check the valve balls (poppets) for proper seating, and look for anything that can cause pump failure. At each overhaul, replace all bad parts that are not repairable. Also replace cure-dated parts (natural or synthetic rubber items) anytime the pump is disassembled. Remove minor scratches and corrosion, or polish them out by using a specified type of crocus cloth. If necessary, clean internal threads with the correct size tap.
Next, clean all external threads by filing or by using the proper size die. Before reassembly, coat all internal parts with clean hydraulic fluid of the type used in the system. After the pump has been reassembled, test it for proof pressure and leakage. Figure 6-12 illustrates a setup for testing the hand pump. Basically it consists of a gage, shutoff valve, reservoir, and tubing. 6-12