FM 1-509 Downloaded from https://www.everyspec.com Operation. Motors operate on the same principles as pumps, but in reverse. If the operation of the motor as illustrated in Fiqure 6-13 is understood, understanding other motors should not be difficult. When the hydraulic system is pressurized, fluid pressure is put on the pistons of the cylinder block. Pressure must also go to the closed starting valve of the motor. Normal system pressure will sustain cylinder and generator rotation, but higher pressure is needed to start the rotation. The starting valve (H) starts the hydraulic motor. When system pressure builds up to 1,800 to 2,200 psi, the starting valve is moved to the right.
This action permits fluid under pressure to move the control piston (K), which moves the bottom of the wobbler plate (A) to the right with sudden force. Movement of the wobbler plate kicks the upper and lower pistons (B) to give the cylinder block an initial spin. Then system pressure maintains the rotation of the cylinder block. As hydraulic pressure continues to increase, motor speed increases. As the rotational speed increases, the governor flyweights (D) begin to pivot outward, moving the governor control valve (C) proportionately to the left. This movement gradually blocks the pressure to the control piston (K).
When the passage is completely blocked, pressure is no longer put on the control piston, and the motor speed ceases to increase. This is referred to as an on-speed condition. The load imposed on the motor varies with the electrical load on the generator. To meet the changing demands, the motor must vary its torque to maintain its normal operating speed. For example, when the motor overspeeds, it causes the governor flyweights (D) to move outward, pulling the governor control valve (C) a little to the left. Movement to the left from the block position vents the control piston (K) passage to return system pressure. This reduces the force acting on the control piston.
Now system pressure acting on the upper piston (B) is greater than the return system pressure on the control piston. The result is that the upper piston in the rotating cylinder block moves the wobbler plate (A) toward the right, reducing the angle of the plate. The reduced angle reduces the torque output and speed of the motor. Movement of the wobbler plate also momentarily activates the preact piston (F) of the flyweight governor. This prevents over-travel of the governor control valve and hastens the motor’s response to changes in load. The preact piston acts when the wobbler plate moves to the right and the control piston moves to the left.
This action forces fluid in the feedback line (J) into the chamber on the left side of the preact piston. When fluid moves into this chamber, the preact piston moves to the right, increasing tension on the governor spring (E) and opposing movement of the governor control valve to the left. Motor speed decreases, and the fluid in the preact piston chamber bleeds off through the restrictor bleed. The governor control valve moves back to the right, blocking the control piston’s passage and holding the wobbler plate in its new position. These events occur almost instantly to match the torque requirement with the load. 6-14