everyspec.com hydraulic manual — Chapter 7 - Pressure-Regulating Devices

Downloaded from https://www.everyspec.com FM 1-509 system pressure is admitted through a connecting line. The Burdon-tube diaphragm reacts to pressure changes in a manner similar to that of the direct-reading gage. The diaphragm’s movement produces electrical signals that are transmitted through connecting wiring to the indicator unit, where they cause the indicator pointer to move. PRESSURE SWITCHES Purpose. A pressure switch opens or closes an electrical circuit in response to a predetermined hydraulic pressure entering the switch from a connected source. Pressure switches on Army aircraft serve two main purposes.

One is to close the circuit of a warning light that shows low pressure in a system. The other is to affect the circuits of solenoid valves in aircraft having dual hydraulic boost control systems; this ensures that operating pressure to one boost system cannot be shut off unless the other boost system is provided with enough operating pressure to fly the aircraft. Some pressure switches are designed with two sets of contacts to provide control for the warning light and solenoid valve. Types. Two types of pressure switches commonly used in Army aircraft are the piston-type pressure switch and the diaphragm-type pressure switch. Piston-Type Pressure Switch.

(See Figure 7-2.) This switch consists of a rectangular-shaped housing, a cylinder bore and piston, an adjustable spring for loading the piston, a microswitch, and linkage for transmitting the piston’s movement to the microswitch. The housing has a port for connecting the switch to a system pressure line and an electrical receptacle for connecting the switch with an electrical circuit. 7-2