everyspec.com — everyspec.com — MIL-HDBK-310: Global Climatic Data for Developing Military Products (PDF Manual)

Downloaded from https://www.everyspec.com MIL-HDBK-310 A brief summary of the ETAC data analysis procedures follows: The selection of the area or areas with the most extreme conditions, as they pertained to a particular element, and the selection of the month or year at which these extreme conditions might be expected to occur, was accomplished subjectively by ETAC. Data from radiosonde stations in or near these areas were processed. The fact that the extreme conditions do not necessarily occur directly over a particular radiosonde site was noted. Adjustments were made to the observed data to more correctly represent the worldwide extreme conditions when deemed appropriate.

For most stations, only about five years of data, usually taken twice a day, were readily available in an acceptable format (complete period of record, data at a sufficient number of intervals) for summarization of reliable statistics. Only data from standard meteorological pressure levels had been recorded for many overseas stations. With the increased distance between standard levels, especially above 700 mb, "straight line" extrapolating procedures introduced the ever- increasing possibility of error if these data were used. In addition, a number of stations had broken periods of record which did not appear to be dependable.

In both of these cases, ETAC indicated that the reliability sought for this study could not be obtained from such data. On several occasions substitute stations had to be used. Records to altitudes above approximately 24 km were incomplete so a more thorough evaluation of these data than the data at lower levels was required. This was accomplished by comparison with data from nearby stations to attempt to establish the validity of the extreme based on a station with more complete data, as well as by spatial analysis. Highest/lowest recorded and 1-, 5-, 10-, and 20-percent extremes are provided.

These percent extremes are based on observed extreme values or are estimates based on observed values; they are not extrapolated extremes obtained assuming a normal (or any other) distribution for the values of a given element. Because upper atmospheric observations are not routinely taken 24 hours per day, but usually only 2 times per day, the percent extremes do not strictly represent the number of hours per month that the value of a given element is equalled or surpassed.

However, since diurnal cycles in the free air below 30 km are small, the distributions as obtained from summaries of original sounding data for each kilometer level for the extreme month and location selected are considered as fairly representative of percent extremes. A comparison was made between the various locations selected in order to arrive at a final most severe extreme for each level. When it was determined that the extreme condition existed either between two stations having sounding data or displaced from a sounding station, extrapolation through spatial analysis and/or subjective evaluation was accomplished in order to obtain a worldwide extreme value for a given element.

Inputs up to 30 km not provided by ETAC are described as follow: For precipitation rate and water concentration in precipitation, reference to supporting technical material is provided in 40.3.2 since these are presented as profiles. Information on hail sizes aloft came from the studies referenced in 40.1.15 for the worldwide surface environment. For inputs on absolute humidity above 8 km, see ref. (50) in 40.3.1.2. The inputs on ozone concentration were taken from the following: (45) Borden, T.R., Jr. (1970) Extreme Values of Ozone Observed in the AFCRL Ozonesonde Network, AFCRL- TR-70-0072, Environmental Research Papers No. 312, AD704547. (46) Kantor, A.J.

(1972) Ozone Density Envelopes up to 30 km for MIL-STD-210B, AFCRL ('XI) INAP No. 96, (Unpublished internal report). The first of these provided background data that was manipulated in the second report to determine values originally provided for MIL-STD-210B, but remain valid. For this revision, background information on ozone concentrations, variability, and temporal and spatial distributions was provided in the following unpublished report: (47) Niedringhaus, T. (1985) Ozone Concentrations for MIL-STD-210C, United States Army Engineer Topographic Laboratories (ETL-GS-LB) File Study Series, Fort Belvoir, VA. 108