Downloaded from https://www.everyspec.com MIL-HDBK-lool/2 ( 3.3.5 Manufactured Concrete Buildings. Manufactured concrete building components can be effectively used in any combination to minimize const~ction e costs and erection time. Manufactured concrete components alSO ensure a standardization of quality while enhancing permanency and lowering maintenance factors . Precast concrete structural systems , wall panels, and slab decking units can be used individually or in combination. Entire prefabricated modules or units have not generally proven to be as economical or flexible as originally desired and should be considered only after thorough investigation. 3.3.6 Mobilization Construction.

Mobilization construction includes planning for rapid expansion of facilities or rapid construction of new facilities when necessitated by emergency conditions. The use of manufactured or systems buildings are especially appropriate for mobilization construction. 3.4 Miscellaneous Components. 3.4.1 Circulation Components. Circulation components must comply with life safety criteria. 3.4.1.1 E2r!l?S. Building layouts should be configured to minimize the need for ramps. Where ramps are required, they must comply with physically handicapped access requirements for length, width, rise, slope, and materials. Exterior ramps must be integral parta of the building design rather than appendages.

3.4.1.2 Stairs. Stairs must comply with all exit and fire protection requirements. Closed risers with abrasive treads are recommended, although open risers may be considered for industrial type facilities. Buildings over G one story in height must have stair, access stair, or ladder access to the roof . 3.4.1.3 Elevators . Elevator cab size shall be based on functional need. They must conform to physically handicapped access criteria unless it can be shown by supporting data that the facility will only be used by able–bodied military personnel . Speeds and capacities should be industry standard recommendations based on facility type and occupant load.

Hydraulic elevators should generally be used for buildings up to four or five stories, and electric elevatora generally should be used for all others. NAVFAC guide specifications NFGS-14200, Electric (Passenger) (Freight) Elevator, and NFGS- 14214, ~aulic (PassenKer) (Freight) Elevator, and DM-3.09, Elevators _ , Escalators, Dumbwaiters, Access Lifts, and Pneumatic Tube Systems contain additional criteria. 3.4.1.4 Escalators. Escalators are convenient yet expensive components and should be used only where specifically required by progrsm. I 10