Downloaded from https://www.everyspec.com tlIL-HDBK-1001/2 4 .6.2 ~~~ys and Fr=. Exterior windows, with the exception of storefront entrances, should generally be operable. Exterior windows should have insulating glass where required for thermal or solar protection. G 4 .6.2.1 ~. Aluminum-framed windows are recommended for most applications . Steel-f rainedwindows should general lY be limited to industrial type facilities. Factory- applied finishes are recommended. Refer to NFGS-O851O, Steel Windows; NFGS- 08520, Aluminum Windows; and NFGS-08529, Aluminum Storm Windows. 4 .6.2.2 y~ .
Wood windows should be limited to new housing facilities, renovation, or retrofit projects due to the high degree of maintenance required. To reduce maintenance costs, factory- applied vinyl or aluminum finishes are recommended. Refer to NFGS-O861O, = Windows. 4 .6.2.3 Section 3 @rtain Walls. Curtain walls as an exterior skin are discussed in of this manual. In addition, refer to NFGS-08900. 4.6 .2.4 character Rep lacement W in~g~. Replacement windows should reflect the of the cxistinR build inK. Where due to exist,ing conditions replacement windows must-be wood ~rame, an aluminum or vinyl panning system to cover existing wood trim should be considered. 4 .6.3 Glass and_Glazing.
The use of reflective or mirror glass should be limited due to possible deterioration of coatings, condensation problems, and general undesirable appearance. Tinted glass for solar reflection is preferred. Comply with the requirements of DOD 4270. 1-M for glass shading and reflectivity. Insulated glass block can be an alternative for exterior G glazing areas in some projects. Excellent thermal-resistant Value, appearance, and creative design options are advantages of glass block, although availability and cost factors require selected usage. Glass block can also be effectively used in interior treatments where light transmission is desired but privacy and acoustical control is required.
Refer to NFGS--O88OO, Glazin&, for general criteria; NAVFAC OM-37 .04, Brigs and Detention Facilities, for criteria on security glazing; and NAVFAC DM–37 .06, Chapels and Religious Educational Faci&@, for criteria On cOlOred glass. 4 ,6.4 ~ardware. NFGS -08710, Finish Hardware, Ooor and Hardware Institute (DH1) standards, and American National Standards Institute (ANSI) standards should be used for selecting builders’ hardware. 4.7 Finishes. Interior design criteria applicable to selection of finishes are described in NAVFAC OM-1.01, as well as in DM-14 .01, InteriOr M.E&!2_&ti Acoustical properties of finishes shall meet applicable criteria established in NAVFAC DM-1.03.
Refer alSO to NAVFAC guide specifications, design manuals, standard “drawings, and publications listed in NAVk’AC P-34 and NAVFAC DM-50. Design manuals and standard drawings for specific building types are listed in NAVFAC P–272 and establish specific criteria for these building types Interior finishes shall also comply with guidelines established in DOD 4270.1-M. 16