Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 Number of coils Stray magnetic field varies in array as power of r given below Except for a two-pole machine, for which the polar leakage field is independent of r to a first approximation, stray magnetic field will increase as r is increased, if other factors remain the same. In the interest of small stray magnetic field, r should be small rather than large. This does not mean, however, that it is necessary to go to unconventional generator designs of smaller radius and greater length than are customary. So far as we know it should be possible to have small stray magnetic field from generators of normal proportions.
Abnormally long and small diameter designs are usually unnecessary, and abnormally short and large diameter designs should be avoided because they will tend to increase stray magnetic field. 7.2,3.3 Effect of iron. Our considerations up to now have been based upon the assumption of an air core (no iron present). The reason for making this assumption is that we can calculate the magnetic field that will be produced by an array of field coils in an air core, but we cannot as yet calculate it when iron is present. Nonetheless, an iron core is present in a machine and even though we cannot calculate its effect we must make some allowance for it.
The assumption of no iron being present is unrealistic for a generator because it has an iron core. The field coils have iron poles inside them; the poles are arranged outside the iron armature, and are in turn surrounded by the iron frame or yoke of the machine. At first sight it might appear that the iron yoke will carry the magnetic flux from pole to pole, keep it from escaping outside the machine, and cause the stray magnetic field to be less than it would be if no iron were present. The limited data we have on the effect of iron indicates chat this expectation is incorrect.
For three small two-pole motors, the measured polar leakage field is about twice as much as the polar leakage field calculated on the assumption no iron is present. The available data on machines with six or more poles indicate that for these, the measured magnetic field is much more than twice as great as the magnetic field calculated on the assumption that no iron is present. As yet we have too little information to warrant any sweeping generalization, except that much remains to be learned about the effect of iron. 7.2.3.4 Uniformity and symmetry.
The decrease in the polar leakage field that is obtained by the use of a large number of poles is dependent upon a high degree of uniformity and symmetry in the construction of the machine. We can see this by referring back to table VII in 7.2.3 1. At 12 meters the calculated stray magnetic field for eight coils, each with a magnetic moment of 93 square meter ampere turns (1,000 square foot ampere turns), is only 0.00007/0.102 - 0.07 percent as much as the stray magnetic field from a single coil of the same magnetic moment. Hence, if we start out with an array of eight exactly equal coils and then slightly strengthen one, even a very slight degree of unbalance 125