Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.3.2.19 Group 4. Group 4 is a single loop in the form of a circle coinci- dent with the brush collector ring farthest from the armature. In the machine we have been considering the angular spread between the takeoff points is b - a degrees. Let b/90 = d, and a/90 = c. The current in the single loop in group 4 is (2d - 2c)(A + B). The preceding conclusion has been reached as a result of thorough study of the current loops involved.

It can also be derived faster by a more intuitive approach With the takeoff points separated by an angular spread of b - a degrees, we have the full output current making a fraction of a turn equal to (b - a)/360. We can consider this the equivalent of one complete turn carrying a current equal to (b - a)/360 times the total current. The output current for the machines is 8(A + B), hence: Loop current = 8 (A + B)(b - a)/360 [7-16] = (2d - 2c)(A + B) [7-17] since we have b/90 - d and a/90 - c This expression can be written in terms of the output current, I = 8(A + B) , as follows:

Loop current = (d - c) 1/4 [7-18] In a minesweeping generator the brush collector rings are several meters in diameter and the armature current is large If (b - a)/360 is an appreciable fraction, the stray magnetic field from the single loop in group 4 will be large, and must be eliminated. 7.3.2.20 Elimination of group 4. There is one and only one practical way of eliminating group 4. The magnetic moment of the single loop in this group is as follows: [7-19] where: A = area of the loop that has the same diameter as the brush collector rings. d - c = angular spread between the takeoff points expressed as a fraction of 90 degrees. I = output current of the machine.

The only ways in which we can make M = 0 are to make A = 0, or d - c = 0. We cannot make the area enclosed by the brush collector rings equal to zero. We can make I = 0 but we then have a generator with zero output current. The remaining alternative, d - c = 0, is the only one that we can use. It means that there is zero angular spread between the takeoff points on the two brush rings, or that the two takeoff points are in line with the axis of the machine. Therefore, this condition must be satisfied in any dc generator or motor designed for minimum stray magnetic field. 146