Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 rings. In a properly designed machine, the armature current from the armature winding to the brush collector rings should have only a small stray magnetic field, regardless of whether the current is equally divided between the different sets of brushes or not. 7.3.2.31 Conclusions on armature cur rent from winding to brush collector 7.3.3 Connections from brush collector rings. 7.3.3.1 The problem. From the brush collector rings the armature current must go to the following: (a) The commutating pole and compensating windings or to the commutating pole winding alone if the machine has no compensating windings.

(b) The machine terminals. The problem is to make the necessary connections in a way that will give rise to only a very small stray magnetic field. Since these connections carry the whole armature current, which is considerable in large minesweeping generators , it is apparent that they must be carefully designed to attain this objective, 7.3.3.2 General principles of solution. The connections can be designed CO have a small stray magnetic field. as follows:

(a) Use three conductors, a central conductor carrying full armature current in one direction and two outer conductors that are symmetrically arranged on opposite sides of the central conductor with each carrying half current in the reverse direction. (b) Keep the conductors as close together as possible, taking into consideration the requirement for insulation between them, This will keep all current loops small and minimize the disturbance caused by departures from exact equality of current division between the outer conductors.

For each machine, the designer must consider the physical arrangement of the different parts, the space available, and innumerable details that will vary from machine to machine. It is impossible to suggest designs here that will be applicable for any and all conditions. The best that can be done is to give two acceptable designs, one for the three-brush collector ring construction and one for the concentric two-brush collector ring construction. These are to be taken as very simple examples illustrating the general principles involved rather than as designs for specific machines 7.3,3.3 Connections for three-brush collector ring construction.

Figure 99 is an example of connections that could be used for a three-brush collector ring machine. The arrows indicate the direction of the current in each conductor. Figure 99 gives the corresponding current loops. We can see that for every current loop there is in the same plane a closely adjacent loop of the same magnetic moment but opposite polarity. The total stray magnetic field should be small. 163