Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.4.2 Number of interpoles. If there are any interpoles at all, there must be as many as main poles in machines designed for small stray magnetic field. This is the usual construction for machines of any appreciable size. When this condition is satisfied, the interposes will produce a stray magnetic field of essentially the same pattern as the main field poles. These, as we have seen before , should produce only a small stray magnetic field if the proper number of field poles is used. The same will be true of the interposes if there are as many of them as there are main field poles.
Some small machines are built with only half as many interpoles as main poles. This gives an unsymmetrical arrangement of interposes as compared to main poles, and the stray magnetic field will be larger than for an equal number of interposes and main poles. Machines that do not have as many interposes as main poles should not be used on minesweepers, no matter what the size of the machine may be. The only exception would be very small machines that have no interpoles at all, 7.4.3 Very bad arrangement of connections. Figure 101 shows an extremely bad arrangement of connections to the interpoles. The whole armature current encloses a large loop around the shaft.
The armature current is large for minesweeping generators and large dc generators and motors used for ship propulsion, and the stray magnetic field produced by such a loop can be enormous. During World War II, a stray magnetic field of more than 4 microtesla was measured 18.6 meters (61 feet) below the waterline. Such a stray magnetic field is far too large for minesweepers or other vessels. Interpole connections such as shown on figure 101 should never be used on machines for shipboard use. 7.4.4 Bad arrangement of connections. Figure 102 shows an arrangement of connections that do not make a complete turn around the shaft, but that are still bad, though not as bad as those on figure 101.
The trouble with this arrangement is that the outgoing and return conductors are not close together, but far apart. They enclose a loop of considerable area between them, which will inevitably give rise to an objectionable stray magnetic field. 7.4.5 Satisfactory arrangement of connections. Figure 103 shows a satisfac- tory arrangement of interpole connections. Connections must be at the same end of the machine and as close together as possible, not separated as shown in the drawing for the sake of clarity. Note also that with connections arranged this way, the current loops they form are in pairs with the two loops in a pair of the same magnitude but opposite polarity.
The net magnetic moment for the loops will thus be zero. 7.5.1 General. 7.5.1.1 Use. Compensating windings are used on large dc motors and generators, including many of the present day minesweeping generators, to compensate armature reaction and improve machine performance. A compensating winding is used on many motors and generators in which a small stray magnetic field is of no consequence whatsoever; hence, it is not a feature that is added to compensate or cancel other magnetic fields in order to arrive at a small stray magnetic field from the machine. 168