Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 TABLE XIV. End connectors and current angles for six pole machine - Continued. 7.5.3.2 Balance at both ends. Inspection of table XIV shows that the sum of the clockwise angles is equal to the sum of the counterclockwise angles, both for the inner connections, which represent the end connectors at one end of the machine, and the outer connectors, which represent the end connectors at the other end of the machine. There are, therefore, zero net turns around the shaft at each end of the machine.
It is to be expected, therefore, that the stray magnetic field caused by the compensating winding will be small, provided that the end connectors at each end of the machine are as close together as possible. This expectation has been verified by tests on a machine that has a compensating winding of this kind and gives a small stray magnetic field. It is vitally important that the clockwise and counterclockwise angles balance at each end of the machine. It is not enough to have a clockwise angle at one end of the machine balanced b) an equal counterclockwise angle at the other end of the machine.
The cancellation of magnetic field caused by this combination is not good enough to be satisfactory. This will be discussed in more detail in 7.5,4,2. The compensating winding of figure 116 satisfies the condition of balance at each end individually. A little consideration will show that a single series circuit compensating winding can always be laid out to satisfy this condition when the number of slots per pole-face is even. 7.5.4 Odd number of slots per pole face. 7.5.4.1 Tabulation of angles. Figure 105 shows a pole-face winding for an eight-pole generator with three slots per pole face.
The clockwise and counterclockwise angles are given in table XV for both the inner and outer connectors . 174