Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 8.1.1.5.3.3 Six-tray arrangement. With six trays we have six horizontal loops and eighteen vertical loops, six in each of three parallel vertical planes. We will divide the twenty four loops into three groups in accordance with 8.1.1.5.3,3.1 through 8.1.1.5.3.3. 3. 8.1.1.5.3.3.1 Group one. Our first group will consist of six horizontal loops. These are equivalent to six Vertical dipoles. 8.1.1.5.3.3.2 Group two our second group will consist of six vertical loops in one vertical plane. 8.1.1.5.3.3.3 Group three. Our third group will consist of the remaining twelve loops in the remaining two vertical planes.
8.1.1.5.3.3.4 Limits on the maximum fields. The field for each group must be determined by deriving an equation using the methods given in appendix A. The limits on the field can be determined as demonstrated in 8.1 1.5.3.1 and 8.1.1.5.3.2. 8.1.1.5.3.4 Importance of equivalent loop areas. We will determine the maximum field values given in 8.1.1.5.3,1.4, 8.1.1.5.3.2.4 and 8.1.1.5.3.3.4 on the assumption that all horizontal loops are of exactly equal area and that all vertical loops are also of exactly equal area. Suppose the areas of the four horizontal loops in a four-tray arrangement are 44,600 square meters (mz), 44,600 m2, 44,600 q 2, and 60,000 q 2.
The magnetic field produced by these will be the same as that produced by a group of four loops of 44,600 m2 each plus a single loop of 15,400 m2 will, for a current of 1000 A, produce a field of almost twenty times the magnetic field of four loops of equal area. This illustrates the need for keeping loop area equal, Also , it is better to use bus bars rather than cable for connecting the trays together because bus bars can be bent into shape with more precision and are more likely to stay in shape. mz. The magnetic field for a group of four loops (see 8.1.1.5.3.2.1) is 0.505 nT.
The single horizontal loop of 15,400 8.1.1.6 External battery circuit connections, We will make external battery circuit connections in order to minimize the creation of stray magnetic fields. External battery circuit cable connections to the bus bar intercell connectors will be made at the bus bar termination points showm on figures 108, 111 and 112, in accordance with the method shown on figure 115. 8.1.2 Batteries in submarines. The design criteria for batteries in submarines will be in accordance with 8.1.2.1 through 8.1.2.5. 185