Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 of wood hull minesweepers. It is sufficient to make sure that the stray magnetic field for submarines storage batteries is small compared to the degaussed field of the submarines. Therefore, it is unnecessary to arrange batteries in submarines so that their stray magnetic field is as small as that from batteries in minesweepers 8.1.2.3 Evaluation of submarine battery arrangement. We will describe and evaluate the small stray magnetic field of submarine batteries in 8.1.2.3.1 through 8.1.2.3 10.6, 8.1.2.3.1 Eight cell batteries.
We will use a battery with eight cells arranged in two rows of four cells each for the example arrangement. The simplest way of connecting these in series is shown in the plan view of figure 116. The battery is shown short-circuited on itself in order to confine our attention to the current loops in the battery itself. In any actual installation, connection to the external circuit would be made at one end of the battery. FIGURE 116. Plan view of series connection. 8.1.2.3.2 Current path. The current in the battery will be distributed over the cross section of the cells, but to a first approximation it can be considered as a concentrated current in a conductor along the center of a row.
This gives the current path shown on figure 117. The two rows of cells give a single, horizontal current loop that will have a substantial stray magnetic field. FIGURE 117. Current path in battery. 8.1.2.3.3 Reduction of stray magnetic field. We can substantially reduce the stray magnetic field by putting in two crossovers (see figure 118), one betweem the first and second cells in a row and the other between the third and fourth. This will break the single current loop (see figure 117) into three current loops (see figure 118). The end loops, 1 and 3, each have half the area 187