Downloaded from https://www.everyspec.com FIGURE 120. Current loops of a battery of eight submarine type cells. 8.1.2.3.6 Rows on different levels. In a submarine, the outboard rows of cells are higher than the inboard rows to conform to the shape of the submarine. Along the longitudinal centerline we may have two or more rows of adjacent cells on the same level. Farther out, adjacent rows of cells will be at different levels. Refer to figure 120 and suppose that the left-hand row of cells is raised bodily upward.
Current loops 1 to 3 will be tilted out of the horizontal plane into an inclined plane, but their relative areas will remain unchanged and their magnetic fields will still be opposed. The vertical loops will remain vertical, and their magnetic fields will also be opposed. Thus the basic scheme used will give a small stray magnetic field regardless of whether the two rows of cells are on the same level or on different levels. 8.1.2.3.7 Preferred arrangement.
If no restrictions were placed upon our choice, the preferred arrangement for submarine storage batteries would have 8 rows of cells on the same level, with 4N cells in each row, where N is an integral number, The rows would be grouped in four pairs of two adjacent rows, with cross- overs placed so that each pair of rows would give three current loops that are N- 2N-N cells long. We would have a total of twelve current loops with polarities as shown on figure 121. The connections from row to row (not shown on figure 121) can be made all at one end of the battery, or partly at one end and partly at the other, in such a way as to give the horizontal loops the polarities shown on figure 121.
The end connections should be as close together as possible to minimize the size of the current loops that they form. FIGURE 121. Schematic representation of Preferred arrangement for submarine storag e battery. 189