Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 8.1.2.3.10 Modifications of preferred arrangement. We cannot use the preferred arrangement without modification unless the number of cells in the battery is an integral multiple of 32 (eight rows with 4N cells in each row), and there is sufficient space available to arrange a battery with eight rows all on the same level. Usually one or both of these conditions will not be satisfied and the preferred arrangement will have to be modified to fit the submarine. 8.1.2.3.10.1 Cells on different level. To conserve space, we arrange the battery in a submarine to conform to the shape of the hull.
The central rows of cells are at the lowest level, and the outer rows at progressively higher levels. This will not result in quite as effective cancellation of magnetic field as if all rows were on the same level, but, as pointed out in 8.1.2.3.6 neither should it result in any great increase in magnetic field. 8.1.2.3.10.2 Number of cells. The preferred number of cells is an integral multiple of 32. Next in order of decreasing preference are integral multiples of 16, 8 and 4. An odd multiple of 2 is undesirable from the stray magnetic field standpoint. Take 126 cells, for example. The current loops in the battery will have a total length of 63 cells.
By suitably positioned crossovers, we can give a plus polarity to current loops with a total length of 31 cells and a minus polarity to current loops with a total length of 32 cells. This creates a net magnetic moment corresponding to a current loop one cell long. At high rates of charge or discharge, this can give rise to a magnetic field large enough to be undesirable. For this reason, it is desirable that the total number of cells in the battery be a multiple of 4 if not a multiple of a higher power of 2. If the total number of cells in the battery is 4N, the total length of current loops will be 2N.
This can be split by suitably placed crossovers into positive and negative loops that each have a total length of N cells. The net magnetic moment will be zero. 8.1.2.3.10.3 Arranging the battery. Space considerations may not permit a battery arrangement with eight rows of equal length. In such cases we must consider the best choice of number of rows, the grouping of the rows , and the number of cells in a row. 8.1.2.3.10.4 Number of rows. Our first choice for the number of rows is a multiple of 8; next, a multiple of 4; and last a multiple of 2. An odd number of rows should never be used except for extremely compelling reasons.
An odd number of rows will inevitably result in a battery that is poorly arranged from the standpoint of small stray magnetic field. 8.1.2 3.10 5 Grouping of rows. . It is preferable to have the battery arranged in groups of 8 adjacent rows of equal length; next in order of preference, groups of 4 adjacent rows of equal length. The reason for wanting to have groups of 4 adjacent rows of equal length is that with these we can have current loops as follows: 191