Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 4 .3.4 Summary of formulas for circular arrays 4 .3.4.1 Circular arrays in the xz plane . Table III summarizes formulas for the maximum value of the vertical component of the magnetic field produced on a plane z meters below the center of a circular array of dipoles in the xz plane. Values are given for two cases: (a) Case 1. Dipoles so oriented that the z axis is in line with one pair of diametrically opposite dipoles. (b) Case 2. Dipoles so oriented that the z axis bisects the angle between adjacent dipoles. 4.3.4.2 Circular arrays in the xy plane.
Table III summarizes formulas for the maximum value of the vertical component of the magnetic field produced on a plane z meters below the center of a circular array of dipoles in the xy plane. Rotating the array in the xy plane will not change the value of the maximum vertical component on a plane below the array, it will merely change the position or the positions w-here the maximum value occurs . TABLE 111. Maximum values of vertical component. 4.3 4.3 Advantages.
It is apparent from table III that it is of some advantage, from the standpoint of small stray magnetic field, to have machines with horizontal axes built such that the z axis bisects the angle between two adjacent main field poles. The advantage to be gained becomes less as the number of poles is increased, but since a machine can be built as easily this way as with two main poles on the vertical axis, it is considered desirable to have the vertical axis bisect the angle between two adjacent main field poles. 4.3.4.4 Vertical axis machines.
Table III also indicates that a very substantial reduction of stray magnetic field from the field coils can be obtained by building generators with a vertical axis such that the main field poles are in the xy instead of the xz plane. Unfortunately, this kind of construction introduces mechanical problems. The use of a sufficient number of main field poles gives a small stray magnetic field even for generators with horizontal axes; hence, it is not necessary to go to a vertical axis construction. 68