Downloaded from https://www.everyspec.com MIL-HDBK-1001/l 1.5.2 Navv Imaee. Architecture for naval facilities should be reflective and supportive of characteristics of the Navy’s image. The Navy’s image is timeless, dignified, and serious. The Navy’s image is honest and rational and it is respectful of being one part of a larger whole. 1.5.3 Cost-Effectiveness. Architecture for naval facilities must be economical and cost-effective by providing necessary scope, function, and quality at the lowest reasonable life cycle cost. The appearance of the facility must also be consistent with economy and cost-effectiveness.
More durable materials can be used when justified on a life cycle cost basis 1.6 Naw as a Client. The Navy is a multifaceted client. The actual user of the facility will be an activity which is part of a systems command. A military base or area public works office may also be involved. NAVFACENGCOM, as the shore facilities design and construction agent for the Navy and occasionally for other agencies , will represent tbe Navy and coordinate functional requirements for facility design. 1.7 Functional Requirements. Functional requirements are defined in project programs, criteria manuals, or other technical references.
Many Navy functions are similar to functions of facilities within the private sector. Personnel housing, for example, is quite similar to a school dormitory or a motel; a maintenance shop or an administration building is much like a private sector building serving similar functions. However, in many cases, there will be some functional requirements for Navy facilities which may differ from the private sector. 1.8 m. Budget is critical in Navy projects. Any significant deviation in anticipated project cost must be defined as early as possible so that adjustments in scope or budget can be made.
The later in the project this occurs, the less flexibility there is to adjust without incurring cost increases and delaying the project. 1.9 Materials and Systems. Select materials and systems to meet requirements of the following facility categories and economic lives: a) Permanent and semi-permanent (nonwood) buildings - 25 years b) Semi-permanent (wood) buildings - 20 years c) Temporary or rehabilitated buildings - 15 years Consider function, appearance, security, resistance to vandalism, life cycle cost, and availability for selection of operating systems. Also consider the size and skill level of the operations and maintenance staff and the conditions under which they will work. 3