3.18. Discharging the Compressed Air Route Regulator and Dry Air System Lubricator Dispose of any water or oil that has accumulated in the compressed air route regulator and dry air system lubricator. For the compressed air route regulator, some models require that water and impurities be discharged manually, while other models discharge water and impurities automatically. Discharging the Compressed Air Route Regulator For models where the water and impurities are discharged manually 1. Close the facility's pressurized air valve. 2. Check that the machine is in the Power Off Status. 3. Set the plastic container under the air filter drain and press the two orange buttons.
Check to see that the accumulated water was discharged. Buttons 4. Open the facility's pressurized air valve. 71 Frequency Everyday User Permissions H Required Items Plastic container and personal protective equipment (protective gloves and clothing)