13. Attach the cap. Make sure that all springs are installed. Make sure that the cap is set horizontally. 14. Secure the cap unit by tightening the screw at the center with the hex key (width: 2.5 mm). 15. Grease may have oozed out of the surface of the lip section. Wipe the lip section gently using the clean stick moistened with maintenance liquid. 16. After replacement, make sure that no tools or other items are left on the print head operating area or carriage operating area. 17. Close the front protection cover. 18. Turn the main power switch to 1 (ON) to turn the power on. 19. Start up Leonardo. 20. Release the emergency stop button. 21. Execute Set point.
On the Leonardo operation screen, click [Setpoint] and then press the reset button on the main electric panel. The head carriage moves to the cleaning station. 97