Specifications Ink Cartridges ∗ The expiration date is indicated on the ink cartridge box. 115 Item Specifications Ink Type See "Supported Ink" on page 112. External dimensions Width (W): 158 mm {6.2 in} Length (D): 389 mm {15.3 in} Height (H): 269 mm {10.6 in} Weight Approx. 11 kg {388 lb} Ink color See "Supported Ink" on page 112. Operating environment conditions with ink cartridges installed (1) Temperature: 20 to 30 °C {68 to 86 °F} (2) Relative humidity: 35 to 85 % (no condensation) (3) The ink in a cartridge that has been left in a low temperature environment will freeze at a temperature of -10 °C {14 °F} or less.
If ink is frozen, thaw it at room temperature and then use the ink after it is within the operating temperature range. Reference: In a 25 °C {77 °F} environment it takes approximately 34 hours for frozen ink to warm from -10 to 20 °C {14 to 68 °F}. Warranty period with ink cartridges installed (1) Temperature/warranty period without I/C installed: -20 to 60 °C {-4 to 140 °F}/ Max. 5 days -20 to 40 °C {-4 to 104 °F}/ Max. 1 month With I/C installed: -20 to 40 °C {-4 to 104 °F}/ Max. 1 month (2) Relative humidity: 35 to 85 % (no condensation) Transport and storage environment (1) Temperature: 10 to 35 °C {50 to 95 °F} (recommended warranty temperature) (2) Relative humidity:
35 to 85 % (no condensation) Recommended lifetime Indicated on ink cartridge labels Orientation during transport and storage During transport and storage, ink cartridges should be oriented as shown below with the largest surface facing up. Label Up Stack height during transport and storage 7 cartridges high