EPSON — Releasing an Emergency Stop Button

Workflow before Beginning Work Releasing an Emergency Stop Button Turn the [Emergency Stop Button] to the right to release the emergency stop status. 45 Set Point cannot be executed if any emergency stop button has been pressed or if the cleaning tank is pulled out because the emergency stop condition has not been released. Confirm that the emergency stop condition has been released at all of the following emergency stop buttons and the cleaning tank.

• Five emergency stop buttons of this machine • Emergency stop buttons for devices linked to this machine (If there are linked devices) • Belt cleaning tank When returning the belt cleaning tank to the original position, check if the two fasteners on the belt cleaning tank are touching the machine, and if the belt cleaning tank is touching the belt cleaning unit position sensor. If there is a gap between the two fasteners on the belt cleaning tank and the machine, or if the belt cleaning tank is not touching the belt cleaning unit position sensor, the machine enters the emergency stop condition and will not operate. Fasteners on the belt cleaning tank Belt cleaning unit position sensor