mg — MG18B250 VLT HVAC Basic Drive Руководство по программированию

Перечни параметров Руководство по программированию привода VLT ® HVAC Basic Drive 5.1.13 16-**Вывод данных 5 5 Таблица 5.14 MG18B250 - VLT ® является зарегистрированным товарным знаком Danfoss 109 Par. No.

# Parameter description Default value 2-set-up Change during operation Conver- sion index Type 16-0* General Status 16-00 Control Word 0 N/A 1 set-up TRUE 0 Uint16 16-01 Reference [Unit] 0.0 ReferenceFeed- backUnit 1 set-up TRUE -3 Int32 16-02 Reference [%] 0.0% 1 set-up TRUE -1 Int16 16-03 Status Word 0 N/A 1 set-up TRUE 0 Uint16 16-05 Main Actual Value [%] 0.0% 1 set-up TRUE -2 Int16 16-09 Custom Readout 0.0 CustomReadoutUnit 1 set-up TRUE -2 Int32 16-1* Motor Status 16-10 Power [kW] 0.00 kW 1 set-up TRUE -3 Uint32 16-11 Power [hp] 0.00 hp 1 set-up TRUE -3 Uint32 16-12 Motor Voltage 0.0 V 1 set-up TRUE -1 Uint32 16-13 Frequency 0.0 Hz 1 set-up TRUE -1 Uint32 16-14 Motor Current 0.00 A 1 set-up TRUE -2 Uint16 16-15 Frequency [%] 0.0% 1 set-up TRUE -1 Uint16 16-18 Motor Thermal 0.0% 1 set-up TRUE 0 Uint8 16-3* Drive Status 16-30 DC Link Voltage 0 V 1 set-up TRUE 0 Uint32 16-34 Heatsink Temp.

0 °C 1 set-up TRUE 100 Uint8 16-35 Inverter Thermal 0.0% 1 set-up TRUE 0 Uint8 16-36 Inv. Nom. Current 0.0 A 1 set-up TRUE -2 Uint16 16-37 Inv. Max. Current 0.0 A 1 set-up TRUE -2 Uint16 16-38 SL Controller State 0 N/A 1 set-up TRUE 0 Uint8 16-5* Ref. & Feedb.

16-50 External Reference 0.0% 1 set-up TRUE -1 Int16 16-52 Feedback[Unit] 0.0 ProcessCtrlUnit 1 set-up TRUE -3 Int32 16-6* Inputs & Outputs 16-60 Digital input 0 N/A 1 set-up TRUE 0 Uint16 16-61 Terminal 53 Setting [0] Current mode 1 set-up TRUE - Uint8 16-62 Analog Input AI53 1.000 N/A 1 set-up TRUE -2 Uint16 16-63 Terminal 54 Setting [0] Current mode 1 set-up TRUE - Uint8 16-64 Analog Input AI54 1.000 N/A 1 set-up TRUE -2 Uint16 16-65 Analog Output AO42 [mA] 0.000 mA 1 set-up TRUE -2 Uint16 16-66 Digital Output 0 N/A 1 set-up TRUE 0 VisStr[4] 16-71 Relay Output [bin] 0 N/A 1 set-up TRUE 0 Uint16 16-72 Counter A 0.0 N/A 1 set-up TRUE 0 Int16 16-73 Counter B 0.0 N/A 1 set-up TRUE 0 Int16 16-79 Analog Output AO45 0.000 mA 1 set-up TRUE -2 Uint16 16-8* Fieldbus & FC Port 16-86 FC Port REF 1 0 N/A 1 set-up TRUE 0 Int16 16-9* Diagnosis Readouts 16-90 Alarm Word 0.0 N/A 1 set-up TRUE 0 Uint32 16-91 Alarm Word 2 0.0 N/A 1 set-up TRUE 0 Uint32 16-92 Warning Word 0.0 N/A 1 set-up TRUE 0 Uint32 16-93 Warning Word 2 0.0 N/A 1 set-up TRUE 0 Uint32 16-94 Ext.

Status Word 0.0 N/A 1 set-up TRUE 0 Uint32 16-95 Ext. Status Word 2 0.0 N/A 1 set-up TRUE 0 Uint32