Chapter 5: Advanced Serverboard Setup Manufacturer Mode Select Close pin 2 and pin 3 of Jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufacturer mode, allowing the user to flash the system firmware from a host server for system setting modifications. See the table on the right for jumper settings. SAS Enable (For X10DRFF-C Only) Jumper JPS1 allows you to enable the onboard SAS connectors. The default setting is 1-2 to enable the connection. See the table on the right for jumper settings. 5-10 Onboard Indicators GLAN LEDs GLAN LED There are two GLAN ports (JLAN1/2) on the serverboard. Each Ethernet LAN port has two LEDs.
The Yellow LED on the right indicates connection and activity. The Link LED on the left side may be green, amber or off to indicate the speed of the connection. See the tables at right for more information. Link Speed LED 5-21 ME Mode Select Jumper Settings Jumper Setting Definition Pins 1-2 Normal (Default) Pins 2-3 Manufacture Mode SAS Enable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled (Default) Pins 2-3 Disabled Activity LED GLAN Activity Indicator (Right) LED Settings Color Status Definition Off No Connections Yellow Flashing Active LAN Connection Speed Indicator (Left) LED Settings LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz