Supermicro FatTwin F618R2-RTPT+/R72PT+ — Supermicro FatTwin F618R2-RTPT+/R72PT+ Server User's Manual PDF

FatTwin F618R2-RTPT+/R72PT+ USER'S MANUAL 2-6 Checking the Serverboard Setup After you install the FatTwin F618R2-RTPT+/R72PT+ in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. Accessing the inside of the System Before operating the server for the fi rst time, it is important to remove the protective fi lm covering the top of the chassis, in order to allow for proper ventilation and cooling. Caution: Except for short periods of time, do NOT operate the server without the cover in place. The chassis cover must be in place to allow proper airfl ow and prevent overheating. Checking the Components and Setup 1.

You may have one or two processors already installed into the serverboard. Each processor needs its own heat sink. See Chapter 5 for instructions on processor and heat sink installation. 2. Your FatTwin F618R2-RTPT+/R72PT+ server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5. 3. If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards. 4. Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. Also make sure that no cables are positioned in front of the fans.

See Chapter 5 for details on cable connections. 2-8