Supermicro FatTwin F618R2-RTPT+/R72PT+ — Supermicro FatTwin F618R2-RTPT+/R72PT+ Server User's Manual PDF

Chapter 5: Advanced Serverboard Setup Notes: 1. For the latest CPU/Memory updates, please refer to our website at http:// www.supermicro.com/products/serverboard/ for details. 2. Use only the correct type of onboard CMOS battery as specifi ed by the manufacturer. Do not install the onboard battery upside down to avoid possible explosion. 3. Jumpers not indicated are for test purposes only. 4. All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual. The serverboard you've received may or may not look exactly the same as the graphics shown in this manual.

5-13 X10DRFR-NT Serverboard Jumpers Jumper Description Default Setting JBT1 Clear CMOS See Chapter 2 JI2C1/JI2C2 SMB to PCI-E Slots Pins 2-3 (Normal) JPB1 BMC Enable Pins 1-2 (Enabled) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1 (For X10DRFR) GLAN1/GLAN2 Enable Pins 1-2 (Enabled) JPL1 (For X10DRFR-NT) 10G-LAN1/10G-LAN2 Enable Pins 1-2 (Enabled) JPME2 Manufacture Mode (ME) Select Pins 1-2 (Normal) JWD1 Watch Dog Pins 1-2 (Reset) X10DRFR-NT Serverboard LED Indicators LED Description State LE1 UID (Unit Identifi er) LED) _ Blue: (On/Blinking) Unit identifi ed LE2 System Power Good LED On: System power on LE3 SATA Activity LED Green (Blinking): SATA active LE4 Standby Power Good LED On:

Standby power on LEDM1 BMC Heartbeat LED Green (Blinking): BMC Normal