Power supply unit (PSU) 6.1 Basic information AC PSU The server can be equipped with up to two hot-plug AC PSUs. In its basic configuration the server has one PSU that adjusts automatically to any mains voltage in the range of 100 V - 240 V (AC PSU Platinum, 450 W) or 200 V - 240 V (AC PSU Titanium, 800 W). Besides the PSU, a second PSU can be installed optionally to serve as a redundant power supply. If one PSU fails, the second PSU in the redundant configuration ensures operation can continue uninterrupted and the defective PSU can be replaced during operation (hot- plug). The second PSU can be installed during operation. V CAUTION!
The AC PSU adjusts automatically to any power voltage in the range from 100 V - 240 V (AC PSU Platinum) or 200 V - 240 V (AC PSU Titanium). You may only operate the server if its rated voltage range corresponds to the local mains voltage. DC PSU The server can be equipped with up to two hot-plug DC PSUs. In its basic configuration the server has one PSU that adjusts automatically to any mains voltage in the range of -40.5 V - -57 V (DC PSU -48 V, 800 W) or 200 V- 380 V (HVDC PSU 380 V, 1300 W). Besides the PSU, a second PSU can be installed optionally to serve as a redundant power supply.
If one PSU fails, the second PSU in the redundant configuration ensures operation can continue uninterrupted and the defective PSU can be replaced during operation (hot-plug). The second PSU can be installed during operation. V CAUTION! The DC PSU adjusts automatically to any power voltage in the range from -40.5 V - -57 V (DC PSU -48 V, 800 W) or 200 V - 380 V (HVDC PSU 380 V, 1300 W). You may only operate the server if its rated voltage range corresponds to the local mains voltage. Fujitsu battery unit (FJBU) Besides the PSU, an FJBU can be installed optionally as a modular UPS. When power fail happened, the server can operate via FJBU for a while.
The FJBU can be replaced during operation (hot-plug). 110 Upgrade and Maintenance Manual RX2530 M4