Power supply unit (PSU) 6.2.1.4 Concluding steps К If applicable, configure the redundant power supply. К "Connecting the power cord" on page 63 6.2.2 Removing a hot-plug PSU Customer Replaceable Unit (CRU) Hardware: 5 minutes Tools: Phillips PH1 / (+) No. 1 screw driver (for DC PSU -48 V) I The procedure of removing an AC PSU or a DC PSU differs only in disconnecting/connecting the power cord. I If a hot-plug PSU should be removed from a redundant configuration, while the system is in operation, proceed the following: К Disconnect the power cord from the dedicated PSU, see section "Disconnecting the power cord" on page 50 .
A CSS error is detected and the message "redundancy lost" is displayed using the iRMC web interface. Your configuration is now non-redundant. The CSS error is only an information. After removing the PSU out of its bay, the CSS error will be cleared automatically. 6.2.2.1 Preliminary steps К Only when replacing a PSU in a non-redundant configuration: "Shutting down the server" on page 49 116 Upgrade and Maintenance Manual RX2530 M4