Power supply unit (PSU) V CAUTION! When replacing a PSU in a non-redundant PSU configuration, the server must be switched off first. Replace the PSU after specifying the one that breaks down at work by revitalization. 6.2.3.1 Preliminary steps К "Locating the defective server" on page 47 К Check which PSU is defective. A PSU is defective when the PSU status indicator lights orange. For more information, see section "Indicators on PSUs (hot-plug PSUs)" on page 431 . К Only when replacing a PSU in a non-redundant configuration: "Shutting down the server" on page 49 К Remove the power cord from the defective PSU, see section "Disconnecting the power cord" on page 50 .

6.2.3.2 Note for servers using CMA (Cable Management Arm) Regarding of replacing PSUs, additional tasks are needed, due to an interference between CMA stopper and the PSUs. К Push the lock spring inward to unlock the CMA stopper (see figure 39 ). V CAUTION! In case of not enough space at the under side, unlock the CMA stopper of the server below and pull out the CMA to the rear side. К Remove the CMA stopper with the mounted crossbar (see figure 40 ). К Hold the CMA stopper, the crossbar and the CMA including cables in the one hand. К Remove the PSU (see figure 41 ) and install the new PSU carefully. I Note for PSU1: