fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Power supply unit (PSU) V CAUTION! In case of not enough space at the under side, unlock the CMA stopper of the server below and pull out the CMA to the rear side. К Remove the CMA stopper with the mounted crossbar (see figure 40 ). К Hold the CMA stopper, the crossbar and the CMA including cables in the one hand. К Remove the FJBU and install the new FJBU carefully. К Mount the complete assembly (CMA stopper, the crossbar and the CMA) again into the rail. 6.3.3.1 Preliminary steps К "Locating the defective server" on page 47 6.3.3.2 Removing the defective FJBU К Remove the FJBU, see "Removing an FJBU" on page 125 .

6.3.3.3 Installing the new FJBU К Install the FJBU, see section "Installing an FJBU" on page 124 . 6.3.3.4 Concluding steps К No steps needed. RX2530 M4 Upgrade and Maintenance Manual 127