Hard disk drive (HDD) / solid state drive (SSD) 7.3.3 Removing 3.5-inch HDD modules Customer Replaceable Unit (CRU) Hardware: 5 minutes Tools: tool-less 7.3.3.1 Preliminary steps К If the HDD module to be removed is combined into a RAID array, please proceed as follows: In order to permanently remove an operational HDD module that is part of a RAID array from the server, you first need to delete the array using ServerView RAID Manager. V CAUTION! All data on all HDDs in the array will be lost when deleting the RAID array! Be sure to back up your data before deleting a RAID array. For more information, see the "ServerView Suite RAID Management" user guide.
140 Upgrade and Maintenance Manual RX2530 M4 RAID level Procedure RAID 0 V CAUTION! RAID 0 provides no data redundancy. In case of an HDD module is defect, all data are lost! RAID 1 RAID 5 Removing an HDD module from a RAID 1 or RAID 5 array will not result in data loss. However, the removed drive needs to be replaced immediately by an HDD module of the same or larger capacity. I After replacing the HDD module, RAID rebuild will be performed as a background process, see section "Performing a RAID array rebuild" on page 99.