Hard disk drive (HDD) / solid state drive (SSD) 7.3.4 Replacing a 3.5-inch HDD module Customer Replaceable Unit (CRU) Hardware: 5 minutes Tools: Phillips PH1 / (+) No. 1 screw driver (if moving installation frame) V CAUTION! Only remove an HDD module during operation if the drive is not currently being accessed. Observe the indicators on the HDD module, see section "Indicators on the hot-plug HDD/SSD module" on page 426 . An HDD module can be replaced while the system is in operation. RAID configuration with a RAID controller: Modular Host Bus Adapter with "Integrated RAID" (IR). RAID levels 0 and 1 are supported for internal HDD configurations.
Modular RAID 0/1 controller with "MegaRAID functionality" (integrated MegaRAID). RAID levels 0, 1,10,5 and 50 are supported for internal HDD configurations. Modular RAID 5/6 controller with "MegaRAID functionality" (MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported for internal HDD configurations. As an option, a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of up to 8 GB is available. RAID configuration without a RAID controller: Please follow the instruction of each software e.g. VSAN, Storage Spaces, and Storage Spaces Direct, provided separately to use the software RAID function of OS or Hypervisor.
All HDD modules (drives) must be uniquely identified so that they can be reinstalled in their original bays later. If this is not done, existing data can be lost. 142 Upgrade and Maintenance Manual RX2530 M4