fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Hard disk drive (HDD) / solid state drive (SSD) 7.4.8 Removing 2.5-inch PCIe SSD modules I This procedure is valid, if the PCIe SSD module is controlled by an onboard controller or by a Retimer card. For more information, see the "NVMe User Guide". I If the PCIe SSD module is controlled by a RAID controller of the PRAID EP5x0i family, the PCIe SSD module can be removed during operation (hot-plug), see section "Removing 2.5-inch HDD/SSD modules" on page 159 . Customer Replaceable Unit (CRU) Hardware: 5 minutes Tools: tool-less 7.4.8.1 Preliminary steps К Identify the physical location of the PCIe SSD module, see section "2.5-inch HDD/SSD configurations" on page 148 and the "NVMe User Guide".

К Prepare the removing of the PCIe SSD module, see the "NVMe User Guide". К Depending on your operating system (see the "NVMe User Guide"), "Shutting down the server" on page 49 . 7.4.8.2 Removing a 2.5-inch HDD/SSD module К Pinch the green locking clips and open the locking lever (see figure 78 ). К Pull the PCIe SSD module out of its bay. 7.4.8.3 Installing a 2.5-inch HDD/SSD dummy module К Install the 2.5-inch HDD/SSD dummy module, see section "Installing a 2.5- inch HDD/SSD dummy module" on page 160 . 7.4.8.4 Concluding steps К If applicable, "Switching on the server" on page 66 . RX2530 M4 Upgrade and Maintenance Manual 165