fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Hard disk drive (HDD) / solid state drive (SSD) 7.4.12.1 Preliminary steps К "Shutting down the server" on page 49 К "Locating the defective server" on page 47 К "Disconnecting the power cord" on page 50 К "Getting access to the component" on page 52 К Release all HDD/SSD modules and pull them out a few centimeters, see section "Removing a 2.5-inch HDD/SSD module" on page 160 . V CAUTION! The HDD/SSD modules need not to be removed completely. But if you want to remove them nevertheless, check if all HDD/SSD modules are uniquely identified so that you can reinsert them into their original bays.

К Release all dummy modules and pull them out a few centimeters, see section "Removing a 2.5-inch HDD/SSD dummy module" on page 156 . 7.4.12.2 Disconnecting cables К Disconnect all SAS/Oculink cables from the HDD backplane. К Disconnect all power cables from the HDD backplane. К If applicable, remove the OOB cable from the HDD backplane, too. 7.4.12.3 Removing the SAS expander board (if applicable) Figure 91: Disconnecting SAS cables К Disconnect the two SAS cables from the SAS expander board. 180 Upgrade and Maintenance Manual RX2530 M4