Description 2.2 Absolute offset limits Definition Absolute offset limits are defined by P-AXIS-00492 and P-AXIS-00493. 1. The monitor is activated. The adjustable minimum/maximum values are limited by software limit switches. Fig. 2: Definition range of absolute offset limits Activate the monitor To activate the relative offset limit monitor, at least one of the limits P-AXIS-00492 or P-AXIS-00493 must be configured with a value ≠ 0. 2. The monitor is activated. If both limits = 0, the monitor is not active. TF5200 | TwinCAT 3 CNC Manual mode offset limits 13 Version: 1.082