U.S. Army Material Command (AMC) AMCP 706-210 — FUZES - Engineering Design Handbook AMCP 706-210 (U.S. Army) PDF Download

Downloaded from https://www.everyspec.com AMCP 706-210 LIST OF SYMBOLS* 4 = Area F = Restraining force .4 = Area of a part F = Trip wire force; tangential force pt = Acceleration f = Force of friction a = Acceleration in g's = Frequency, of oscillation /, = Frequency received B = Belleville spring parameter I = Frequency tranmitted b = Width C = Capacitance G = Torque C = ApcitanteG = Shear modulus of elasticity C =A constant C = Coefficient of power deried G! = Frictional torque = G = Initial spring torque c = A constanto CL = Velocity of electromagnetic waves G = Static frictional torque Velocity of sound waves g = Acceleration due to gravity.

32.2 ft/sec 2 d = Mean diameter; caliber A constant d = Inner diameter H e = Electrical energy H/ Power output d = Outer diameter P od 0fi Diameter of a pin H = Potential energy d ff= Diameter of a wire Het d h = Angular momentum E = Young's modulus of elasticity hc = Clearance between coils E = Voltage across a capacitor h = Solid height of a spring C E = Extinction potential of a diode SI = Moment of inertia E = Generated voltage = 2nd moment of area E Minimum operating voltage I = Moment of inertia of escapement system E = Striking potential of a diodea En = Moment of inertia of escape wheel E6 = Battery voltage h = = Free height of a spring F = Generalized force = Current F = Centrifugal force C J = Polar moment of inertia F = Coriolis force CO F , = Creep force K 0 = Drag coefficient Fd = Detent force K = Wahl factor F 0 = Drag force k = Spring constant F = Form factor k = = Proportionality constant F = Force on gear tootih S F = Normal force I = Length * Symbols that bear subscripts other than those shown here are defined in their immediate context.