Installation of the Foams Before installing the Center Platen, make sure you check the foams that are stuck on the Vacuum Beam. These foams should ONLY be changed if they are damaged. In the circumstance where they do need to be changed, use the following illustrations to guide you: Removal & Installation Foams will need to be trimmed when stuck to the Vacuum Beam NOTE: Make sure you take note of the positions of the Foams located underneath the center Platen. NOTE: When reinstalling the parts, make sure you apply the grease (included with the support part) to the gears. NOTE: After installing the NEW Center Platen, make sure you perform the following Service Calibration:
• Paper Advance Calibration ⇒ Chapter 5. NOTE: To simplify the installation of the OMAS an Attachment Screw Retainer has been added to hold the two T-20 attachment screws. This part is delivered with the Center Platen in case either of the OMAS attachment screws are completely removed during the removal of the Center Platen. OMAS Attachment Screws Completely Removed during Center Platen Removal 1. Completely remove OMAS from the Printer ⇒ See Center Platen 405