RUN: The oscilloscope is running. Caution: You must install the software before using the oscilloscope. 1.While in Windows, insert the installation CD into the CD-ROM drive. 2.The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run Setup.exe. 3.The software Installation is started. Click 'Next' to continue. 1. The Main Menu: All settings can be found in the main menu. 2. The Toolbar 3. Displays the trigger information: Displays the edge trigger slope, source and level. 4. The Connect Panel 5. The Horizontal Panel: The user can change Time/Div, format in the panel. 6. The Vertical Panel: The user can turn on/off the CH1/CH2/CH3/CH4.

Also the user can change the CH1/ CH2/CH3/CH4 volt/div, coupling and probe attenuation. 7. The Trigger Panel: In this panel, the user can change the trigger mode, sweep, source and slope. 8. Marker shows Edge trigger level 9. Move Wareform 4.Choose a destination directory. Click 'Next' to continue. GETTING START GETTING START INSTALL 10. Displays the system time. 11. Sample rate 12. The markers show the CH1/CH2/CH3/CH4 reference points of the displayed waveforms. If there is no 13. Connect marker,the channel is not displayed. 14. Displays the CH1/CH2/CH3/CH4 information: Readouts show the coupling of the channels. Readouts show the vertical scale factors of the channels.

A “B” icon indicates that the channel is bandwidth limited 15. Marker shows horizontal trigger position. 16. Trigger status indicates the following: AUTO: The oscilloscope is in auto mode and is acquiring waveforms in the absence of triggers. Trig’D: The oscilloscope has seen a trigger and is acquiring the post trigger data. STOP: The oscilloscope has stopped acquiring waveform data.

Стр. 1

5. Check the start information. Click Next to start copying of files. 7. Updating Your System Configuration. 8. After software Installation it can be start the Device Driver Installation. Click Next to start the Device Driver Installation. 6. This Status dialog is displayed during copying of files.

Стр. 2

9. After software Installation it can be start the Device Driver Installation. Click Next to start the Device Driver Installation. Headquarters Qingdao Hantek Electronic Co., Ltd http://www.hantek.com Address: 2/F., Zone D2, No. 112 Keyuan Longitude 7th Road,Qingdao City, Shandong Province, China 266101 Tel: +86-532-88703687 / 88703697 Fax: +86-532-88705691 Email: service@hantek.com.cn Technical Support Tel: +86-532-88703687 (ext: 634) Email: support@hantek.com.cn Marketing Department Tel: +86-532-88703687 (ext: 603) ACCESSORIES ACCESSORIES SERVICES AND SUPPORT SERVICES AND SUP X1, X10 two passive probes.

The passive probes have a 6MHz bandwidth (rated 100Vrms CAT III) when the switch is in the X1 position, and a maximum bandwidth (rated 300Vrms CAT II) when the switch is in the X10 position. Each probe consists of all necessary fittings. A USB line, used to connect external devices with USB interface like a printer or to establish communications between PC and the oscilloscope. A Switching Adaptor with Output is 12V DC. A software installation CD and it contains the user manual for the oscilloscopes.