3 External Illumination Control and Wiring External Illumination Control and Wiring Lighting The HAWK MV-4000 supports external lighting with Omron Microscan's NERLITE Smart Series lights. The diagrams below demonstrate how the camera and light can be configured with the QX-1 interface device and light kit Y-cables. The light is controlled using the lighting control in AutoVISION Software’s camera configuration settings. HAWK MV-4000 and Smart Series Light Configuration: QX-1 In Strobe mode, the external illuminator is strobed with the exposure of the camera to maximize light for the short exposure times needed in dynamic applications.
ON/OFF mode allows the external illuminator to be enabled and disabled using the HAWK MV-4000’s I/O. Control is achieved using Output 3 on the camera.
9 1 1 1 7 3 4 5 2 6 8 HAWK MV-4000 Smart Camera Guide 3-3 Item Description Part Number 1 Smart Series Light NER-011660XXXG 2 QX-1 Interface Device 98-000103-02 3 Cable, Adapter, HAWK MV-4000 to QX-1 61-9000132-01 4 Cordset, Common, M12 12-Pin Socket to M12 12-Pin Plug, 1 m 61-000162-02 or Cordset, Common, M12 12-Pin Socket to M12 12-Pin Plug, 3 m 61-000148-02 5 Cable, Power, Smart Series to QX-1 61-000204-01 6 Power Supply, 100-240VAC, +24VDC, M12 12-Pin Socket 97-000012-01 7 Cordset, Host, Ethernet, M12 8-Pin Plug to RJ45, 1 m 61-9000134-0X 8 Photo Sensor, VIS, NPN, Light On/Dark On 99-9000016-01 9 HAWK MV-4000 Smart Camera