omron — General Care and Cleaning

C HAWK MV-4000 General Specifications Electrical Specifications General Specifications a. The PTC is an automatically resetting fuse. b. This occurred under the following condition: output pulled to 24 V using 1 kW. c. Regardless of whether the signal is sinking or sourcing, this measurement is the same. d. Maximum input current at max. ON voltage. The connected device must not limit the current to a value lower than this. e. Minimum input current at min. ON voltage. Can be used to calculate bleeding resistor needed for 2-wire proximity sensor. f. Recommended > 12 V when using HAWK MV-4000 breakout board.

HAWK MV-4000 Smart Camera Guide C-5 HAWK MV-4000-03, -03C, -13, -13C, -20, -20C, -50, -50C Operating voltage for the HAWK MV-4000 under testing conditions 24 V Rated current 600 mA Operating voltage tolerance ± 10% I/O Specifications Optoisolated Output Signals Operating Voltage 24 V (26 V abs. max.) Sink Current 50 mA max. Maximum Leakage Current 1 mA@ 24 V 1 mA@ 26 V ON Voltage 0.4 V @ 2 mA 1.1 V @ 25 mA 1.5V @ 50 mA PTCa Fuse Max. Time-to-Trip 1 sec @ 0.5 A OFF-to-ON Response 2 ms to reach 4 Vb ON-to-OFF Response 50 ms to reach 11 Vc Optoisolated Input Signals Operating Voltage 24 V (26 V abs.

max.) Input Current (Sink or Source) 3.5 mA max.d, 1 mA min.e ON Voltage Level > 11 Vf OFF Voltage Level OFF-to-ON Response 6 ms ON-to-OFF Response 80 ms 0-10 V Analog Control Output Signal Non-isolated. Note that the 0-10 V is intended for reference voltage only ( Varioptic Caspian C-39N0-160-I2C or C-39N0-250-I2C Liquid Lens Typical Supplied Voltage 5 V Rated Current 50 mA