Hantek — 3.3.2 SOURce<n>:MOD:ASKey:INTernal:RATE

Command system EN 3.3.1 SOURce :MOD:ASKey:AMPLitude Command format SOURce :MOD:ASKey:AMPLitude |MINimum|MAXimum SOURce :MOD:ASKey:AMPLitude? [MINimum|MAXimum] Function description Set the amplitude of the ASK modulated wave. argument Instructions None Return format Return the amplitude value as a scientific count. Example SOURce1:MOD:ASKey:AMPLitude 1 /* Set the modulated wave amplitude for channel 1ASK modulation to 1Vpp */ 3.3.2 SOURce :MOD:ASKey:INTernal:RATE Command format SOURce :MOD:ASKey:INTernal:RATE |MINimum|MAXimum SOURce :MOD:ASKey:INTernal:RATE?

[MINimum|MAXimum] Function description Set the rate at which the output frequency "moves" between the carrier frequency and the jump frequency. Argument Instructions None Return format HDG300C Programming manual Copyright © Qingdao Hantek Electronics Co., LTD 12 Name Range Default value TYPe 0 Vpp to 20 Vpp 2Vpp Name Range Default value TYPe 2 mHz to 1 MHz 100Hz