hengstler · 2 стр.
Hengstler 486 - 487 Adding Preset Counter Datasheet
Related manuals
Document text
email: sales@impulseautomation.co.uk web: www.impulseautomation.co.uk Adding Preset Counter, Plug-in System Type 486/487 P reset value continuously visible Manual, electric or automatic reset 3 or 5-digit indication Plugs into modular system 400 TECHNICAL DATA Display 3 or 5-digit indication of count and preset value, depending on version Digit height 4 mm Supply voltage V op see ordering code table, tolerance ± 10 % 230 VAC + 6–10 % Power consumption counter: DC version 2.5 W, AC version 2.75 VA reset solenoid: DC version 12 W, AC version 16 VA Residual ripple 48 % Operating temperature – 10 … + 50 °C Storage temperature – 40 …
+ 85 °C Electrical connection AMP connector, 0.8 x 2.8 mm (with connection box) Mounting modular system 400 Mounting position roller axis horizontal Protection class front IP 30; connections IP 00; for higher degree of (EN 60529) protection we recommend a protective case with clear cover (see "Accessories") General design EN 61010-1, EN 50178 Protection according to class II Contamination level 2 Over voltage category II Duty cycle at 25 °C Counter 100 %; reset solenoid: DC version 20 %, max. 2 minutes, AC versions 10 %, max. 1 minute at 50 °C Counter 50 %, max. 10 minutes Maintenance-free operation Counter 2 x 10 8 , reset solenoid 1.5 x 10 6 pulses Approvals UL:
E 41 784-11 Count input adding Min. pulse length DC version 20 ms, AC version 50 ms Max. counting frequency DC version 25 Hz, AC version 10 Hz Pulse duty factor 1:1 Reset - manual with button external by electrical signal (versions with reset solenoid only), Min. pulse length 200 ms (max. see duty cycle); for longer reset pulses a continuous duty module must be used (see "order information" and "accessory modules") automatic reset after preset has been reached (versions with reset solenoid only), using the automatic reset (see "order information" and "accessory Reset frequency DC version max. 1 per s, AC version max.
1 per 2 s Pulse duty factor DC version 1:5, AC version 1:10 Signal output Signal duration from when preset has been reached until reset Contact type Changeover contact, floating Switching voltage max. 220 VAC Switching current max. 20 VA/1 A, non-inductive Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC072 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 24-10-19 1 of 2
Technical data Type 486/487 DIMENSIONS With connection box With connection box and panel frame All dimensions in mm CONNECTION DIAGRAM ORDER INFORMATION Voltage 3 digits 5 digits automatic button reset el. reset button reset el.
reset reset ** ** Counter 12 V DC 0 486 160 0 486 760 24 V DC 0 487 164 0 487 764 0 486 164 0 486 764 1 486 402 48 V DC 0 487 168 0 486 168 0 486 786 60 V DC 0 487 771 110 V DC 0 487 174 0 486 174 4 220 V DC 0 487 780 0 486 180 0 486 780 24 V AC 0 487 186 0 487 786 0 486 186 0 486 786 1 486 409 42 V AC 0 487 788 0 486 188 0 486 788 48 V AC 100 V AC 0 487 198 0 487 798 0 486 198 0 486 798 115 V AC 0 487 189 0 487 789 0 486 189 0 486 789 1 486 412 200 V AC 0 487 799 230 V AC 0 487 190 0 487 790 0 486 190 0 486 790 1 486 413 Standard accessories Connection box Ordering Code 1 405 537 Key-reset system Ordering Code + SR e.g.
0 487 164 SR Panel frame, black Ordering Code 1 405 492 For further accessories see "Accessories" * * on request ** For technical data and dimensioned drawings see accessory modules on page 209 Use only counters with electrical reset. The connection box is integrated in the module. Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC072 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 24-10-19 2 of 2