Shift Counter Shift Counter Function code F5, Display Row 1 : Function code F10, Display Row 1 : With / without Preset 0 With Preset Signal time P 0 Total Sum 0 Disabled / no output signal 1 Bistable; reset with Reset 1* Without Preset 2 0,02 s Function code F6, Display Row 1 : 3 0,05 s 0* Static reset (reset as long as signal is applied) 4* 0,10 s Dynamic/ static Reset Dynamic Reset (ready to count after reset, even if reset signal is applied for a longer time) 1 5 0,20 s 6 0,50 s Function code F9, Display Row 1 : 7 1,00 s Output signal 0* Active On 8 2,00 s 1 Active Off 9 5,00 s 10 10,00 s 11 User setting 1 (0-599,99 s) 12 User setting 2 (0-599,99 s) 13 User setting 3 (0-599,99 s) 88 89